Technical data

Acoustic requirements EPLF/FEP-requirement (Enhanced requirement) ONE / ONE + AIR / AIR+ MMFA-requirement
(Enhanced requirement)
VIN VIO® VIN+ VIO®+ VINYL SK
Radiated walking sound (RWS)1,2)
Reduction in sound emission in the room, even when walked on
tested according to
EPLF draft standard
021029-5
10% 30% - - - - - -
Radiated walking Sound (RWS)1,2)
Noise emissions generated inside the room itself when walking on the flooring
≤ 110 Sone 84,7 / 98,3 Sone 81,8 / 79,7 Sone - 59,8 Sone 62,4 Sone 59,9 Sone 62,6 Sone -
Impact sound reduction (IS)1,2)
Reduction in impact sound in adjacent rooms and rooms underneath
14 dB
(18)
19 / 20 dB 20 dB 10 dB
(18)
21 dB3) 18 dB3) 21 dB3) 18 dB3) 17 dB3)
Usage- requirements
Dynamic load (DL)
Retains essential properties, provides mechanical protection
≥ 10.000 cycles
(100.000)
≥ 10.000 cycles ≥ 1 Mio. cycles ≥ 10.000 cycles
(100.000)
≥ 1 Mio. cycles ≥ 1 Mio. cycles ≥ 1 Mio. cycles ≥ 1 Mio. cycles ≥ 200.000 cycles
Compressive Creep (CC)
Long-term retention of essential properties (10 years)
≥ 2 kPa
(20)
≥ 2 kPa 40kPa ≥ 10 kPa
(35)
35 kPa 40 kPa 35 kPa 40 kPa 40 kPa
Compressice Strength (CS)
Protects the joining systems, protects joints from reputure
≥ 10 kPa
(60)
≥ 40 kPa ≥ 140 kPa ≥ 200 kPa
(400)
≥ 400 kPa ≥ 700 kPa ≥ 400 kPa ≥ 700 kPa ≥ 600 kPa
Impact resistance (RLB)
Protects the surface from falling objects
≥ 500 mm
(1200)
800 mm 1200 mm - - - - - -
Structural requirements
Thermal resistance (λ,Β)2)
Suitable for underfloor heating (H) or cooling (C) below the underlay
≤ 0,15 m2K/W 0,044m2 K/W 0,053m2 K/W ≤ 0,15 m2 K/W 0,020m2 K/W 0,016m2 K/W 0,020m2 K/W 0,016m2 K/W 0,016m2 K/W
Punctually conformability (PC)
Prevents sound bridges, provides mechanical protection
> 0,5 mm 1,1mm 1,4mm > 0,5 mm 0,8 mm 0,5 mm 0,8 mm 0,5 mm 0,5 mm
Moisture (SD)
Protects against damage from moisture
> 75 m - / 75 m - / 200 m > 75 m - 75 m 80 m 100 m 75 m
Absorption of water(WA)
Encourages growth of mildew
EN 12087
(not a requirement, from EPLF)
< 1% < 1 % EN 12087
(not a requirement from MMFA)
< 1% < 1% < 1% < 1% < 1%
1} Values for reduction in impact sound and improvement in football noise are tested in accordance with standard set-ups. These values may vary in practice due to the individual types of building and building products and their arrangement. 2) in this case, the entire floor convering system is tested and assessed 3) tested under vinyl design flooring